Legacy | Edit.Get image

  • Command: edit-image

  • Subcommand: get

  • Supported Platforms: Native (legacy), UFT (legacy), Selenium, Appium

    All commands must be executed using the same framework. Sharing the execution ID between different frameworks is not possible. This means that if you work with a Selenium/Appium driver, you need to call the commands using the Selenium/Appium driver (or, in the case of Reporting commands, through the Reporting SDK that works with the driver) and not as part of a UFT test or another framework.

  • Supported OS: Android, iOS

Description

Identifies an edit field based on an image label and retrieves its value. The value can be inserted into a defined variable.

The field is in relation to the found label and is defined by the label position and offset parameters. For more information, see Visual Relations.

By default, the find image function searches for the image on the current screen. However, if there is a possibility that the image is not on the current screen, enable the Scroll and search parameter. When enabled, the default scroll direction is down. For iOS devices, the default scroll direction is right. To change the scroll direction to down, select body in the Search area parameter.

For more information on how to use the Next parameter, see Create custom swipe gestures

Parameters

Name Value Default Description
deviceId*     The device for this command.
label*    

The image that appears on, or related to, the edit field.

Image should be in JPEG, PNG or BMP format.

label.direction

left (Left)

right (Right)

above (Above)

below (Below)

left-above (Left-Above)

left-below (Left-Below)

right-above (Right-Above)

right-below (Right-Below)

 

The label position relative to the edit field.

Left - The label is to the left of the searched edit field

Right - The label is to the right of the searched edit field

Above - The label is above the searched edit field

Below - The label is below the searched edit field

Left-Above - The label is to the left and above the edit field

Left-Below - The label is to the left and below the edit field

Right-Above - The label is to the right and above the edit field

Right-Below - The label is to the right and below the edit field

label.inline

horizontal (Horizontal)

vertical (Vertical)

none (None)

 

The label alignment, in line with the edit field.

Note: When the Label position is Left/Right, the default is Horizontal.

lines

   

The number of text lines to be retrieved from the edit field.

variable

   

The variable name to receive the edit field text.

The text will always be available in the report.

source

primary (Primary)

native (Native)

camera (Camera)

auto (Auto)

secondary ()

 

The source for retrieving the screen content.

Primary - Screenshot taken from the device (higher resolution but slower)

Native - Native device controls

Camera - Screenshot taken from the video stream (lower resolution but faster)

Auto - Native device controls, if available. Else, digital screen image, if available. Else, analog screen image.

timeout

 

20

The time, in seconds, to wait for the label to appear.

For a dynamic screen, specify the expected waiting time for the label to appear. For example, the page loading time.

The timeout contains the system analysis time, for this reason it is recommended to specify at least 20 seconds.

report

all (All)

all-on-error (All on error)

screenshot (Screenshot)

screenshot-on-error (Screenshot on error)

text (Text)

none (None)

All

The value to display in the report.

Screenshot - display screenshot

Screenshot on error - display screenshots only for actions in error

Text - display screen text

All - display screenshot and text

All on error - display text always and screenshot only for actions in error

None - display nothing

Consider reducing the resolution in very long scripts that result in large report files.

threshold

   

The acceptable match level percentage, between 20 and 100.

Too low values can lead to a false positive result, while too high values can lead to a false negative result.

scrolling

noscroll (False)

scroll (True)

False

Scroll until the label is found.

Scroll cannot be used together with a positive Timeout, because they dictate a different behaviour when the needle is not found. When scrolling is enabled, the timeout must be zero.

Scroll results in a longer execution time.

maxscroll  

5

The maximum number of scroll actions to perform before returning.

Finding the label will stop the scrolling.

Effective values are in the range of 0-100.

key

   

The full repository path, including directory and file name, where to save the screen text. Example - PRIVATE:dir1/screenText.txt. The text will always be available in the report.

image.top

   

The top value of the image area defining the label.

Value is in pixels. Default is the entire image.

image.height

   

The height value of the image area defining the label.

Value is in pixels. Default is the entire image.

image.left

   

The left value of the image area defining the label.

Value is in pixels. Default is the entire image.

image.width

   

The width value of the image area defining the label.

Value is in pixels. Default is the entire image.

match

identical (Same size)

similar (Any size)

bounded (Bounded size)

 

The needle comparison method.

Same Size - needle and haystack are from the same origin (device screen) and size, matching is faster and simpler

Any Size - needle and haystack are either not from the same origin (needle is from another device or other source) or not in the same size (different ratio or size), matching is slower and more complex. Selecting Any Size increases the analysis time. The timeout values should respectively be increased.

Bounded Size - same as Any Size with restrictions on possible needle sizes. This mode allows decrease the any size analysis time by using apriori knowledge on needle sizes or by decreasing the size of a haystack.

profile

default (Default)

DocumentConversion_Accuracy (Document Conversion Accuracy)

DocumentConversion_Speed (Document Conversion Speed)

DocumentArchiving_Accuracy (Document Archiving Accuracy)

DocumentArchiving_Speed (Document Archiving Speed)

BookArchiving_Accuracy (Book Archiving Accuracy)

BookArchiving_Speed (Book Archiving Speed)

TextExtraction_Accuracy (Text Extraction Accuracy)

TextExtraction_Speed (Text Extraction Speed)

FieldLevelRecognition (Field Level Recognition)

BarcodeRecognition (Barcode Recognition)

 

Use when text cannot be found on the device screen.

Try all the profiles with the word accuracy. Per profile, try changing the DPI (96 or 300 or 120).

ocr

   

A generic OCR parameter.

Use this to provide additional OCR specifications that are not exposed as function parameters.

Example - "isolate=true" It is possible to provide multiple specifications.

This parameter is not relevant when using native screen source.

analysis

full (Full)

automatic (Automatic)

manual (Manual)

 

The image analysis mode. The device screen may contain text and images.

Automatic - OCR distinguishes between text and images, filtering out images.

Manual - OCR assumes text only. Use alongside the Inverted text parameter.

Full - OCR tries both automatic and manual.

This parameter is not relevant when using native screen source.

inverse

any (Any)

yes (Yes)

no (No)

 

The text appearance, likely to appear in inverted colors (dark text on light background). Use only if 'Analysis mode' is set to 'Manual'.

Yes - Text is inverted

No - Text is normal, not inverted

Any - Text might be inverted or not, checked automatically by the system

This parameter is not relevant when using native screen source.

screen.top

   

The top value of the screen area where to search for the label.

Values can be in pixels or in percentage of screen width (0-100). For percentage, use the % sign. Example: 20%

Default is to search the entire screen.

Consider reducing the resolution in very long scripts that result in large report files.

screen.height    

The height value of the screen area where to search for the label.

Values can be in pixels or in percentage of screen width (0-100). For percentage, use the % sign. Example: 20%

Default is to search the entire screen.

Consider reducing the resolution in very long scripts that result in large report files.

screen.left

   

The left value of the screen area where to search for the label.

Values can be in pixels or in percentage of screen width (0-100). For percentage, use the % sign. Example: 20%

Default is to search the entire screen.

Consider reducing the resolution in very long scripts that result in large report files.

screen.width

   

The width value of the screen area where to search for the label.

Values can be in pixels or in percentage of screen width (0-100). For percentage, use the % sign. Example: 20%

Default is to search the entire screen.

Consider reducing the resolution in very long scripts that result in large report files.

matchGeneric

   

A generic image compare parameter.

Use this to provide additional image compare specifications that are not exposed as function parameters.

Examples:

matchMethod=TM_SQDIFF_NORMED

matchMethod=TM_CCORR_NORMED

relation.direction

left (Left)

right (Right)

above (Above)

below (Below)

left-above (Left-Above)

left-below (Left-Below)

right-above (Right-Above)

right-below (Right-Below)

inside (Inside)

 

The direction of the related region, stored in memory from the last found needle, in relation to the searched needle.

For more information, see the Visual Relations series.

Left - The related region is to the left of the searched needle

Right - The related region is to the right of the searched needle

Above - The related region is above the searched needle

Below - The related region is below the searched needle

Left-Above - The related region is to the left and above the searched needle

Left-Below - The related region is to the left and below the searched needle

Right-Above - The related region is to the right and above the searched needle

Right-Below - The related region is to the right and below to the searched needle

Inside - The searched needle is inside the related region boundaries of the related region

relation.inline

horizontal (Horizontal)

vertical (Vertical)

 

The search area is in-line with the related region, stored in memory from the last found needle.

For more information, see the Visual Relations series.

Horizontal - The needle is within the height (top to button) boundaries of the related region

Vertical - The needle is within the width (left to right) boundaries of the related region

report.resolution

high (High)

medium (Medium)

low (Low)

High

The image resolution.

Consider reducing the resolution in very long scripts that result in large report files.

language

English (English)

Spanish (Spanish)

Japanese (Japanese)

German (German)

French (French)

Dutch (Dutch)

Italian (Italian)

ChinesePRC (Chinese)

Russian (Russian)

PortugueseStandard (Portuguese)

 

The OCR language to use.It is possible to select multiple languages.

For languages that do not appear in the drop down menu, contact Perfecto Support to enable them.

This parameter is not relevant when using native screen source.

policy

auto (Auto)

accuracy (Accuracy)

performance (Performance)

Auto

The text recognition accuracy policy.

Selecting the Accuracy value will increase the operation time.

Auto - shifted toward recognition accuracy with a moderate impact on the recognition speed.

Accuracy - shifted toward maximum recognition accuracy.

Performance - shifted toward recognition speed.

This parameter is not relevant when using native screen source.

usecache

use (Use)

nouse (No Use)

Use

Indicates whether the text recognition application should use a cached picture of the screen if available (this value should not be changed by the user, under normal circumstances).

interval

 

0

The minimum time interval, in seconds, for a single analysis.

If the analysis operation takes less than the interval, wait the remaining time before the next analysis operation.

backlight

   

The key sequence to perform the backlight operation.

Example - VOL_UP

For best practice, use a key that will not change the screen.

next

SWIPE_UP (SWIPE_UP)

SWIPE_DOWN (SWIPE_DOWN)

SWIPE_RIGHT (SWIPE_RIGHT)

SWIPE_LEFT (SWIPE_LEFT)

UP (UP)

DOWN (DOWN)

RIGHT (RIGHT)

LEFT (LEFT)

 

The key sequence to perform the scroll operation.

For more information see Swipe Gesture in Analysis Functions.

grid

   

The column name to be used for grid view in the report.

Selecting this parameter creates the grid report.

imageBounds.needleBound

   

The ratio in percentage by which the original needle width may vary. The ratio is defined as a (100 - specified percentage) / 100.

Needle sizes to be checked by the analysis will be limited to the range from original needle width multiplied by the ratio to the original needle width divided by the ratio.

To use this parameter, Match mode must be bounded size.

imageBounds.haystackArea

 

786432

The size of haystack to be used for the analysis.

The haystack image will be scaled before being analyzed so its area does not exceed the specified value.

Haystack images that do not exceed the value will stay unchanged.

To use this parameter, Match mode must be bounded size.

* Mandatory parameter

Request & Response

Copy

Request

 https://mycloud.perfectomobile.com/services/executions/john@perfectomobile.com_controller_16-11-07_19_58_34_522?operation=command&user=john@perfectomobile.com&password=123456&command=edit-image&subcommand=get&param.deviceId=6370E775&param.label=PRIVATE:temp%20media\grid-collect-point-icon.png
Copy

JSON response

{
  "reason": "Success",
  "timer.elapsed": "3203",
  "returnValue": "",
  "testGridReportUrl": "https://mycloud.reporting-stg.perfectomobile.com?externalId[0]=john@perfectomobile.com_controller_16-11-07_19_58_34_522",
  "screenAnalysis.analyzedRegion.height": "220",
  "description": "Success",
  "timer.system": "3203",
  "completed": "true",
  "screenAnalysis.analyzedRegion.left": "207",
  "flowEndCode": "SUCCEEDED",
  "screenAnalysis.analyzedRegion.top": "1345",
  "screenAnalysis.resultRegion.left": "207",
  "screenAnalysis.resultRegion.height": "220",
  "screenAnalysis.resultRegion.top": "1345",
  "executionId": "john@perfectomobile.com_controller_16-11-07_19_58_34_522",
  "timer.ux": "0",
  "singleTestReportUrl": "https://mycloud.perfectomobile.com/nexperience/singletest/report/?reportRepositoryKey=PRIVATE:controller/161107/controller_16-11-07_19_58_34_522.xml&ownerId=john@perfectomobile.com&sharingCode=3eff0387-e7b0-4c0a-af43-419f95dc36ec",
  "screenAnalysis.analyzedRegion.width": "873",
  "screenAnalysis.resultRegion.width": "873",
  "reportKey": "PRIVATE:controller/161107/controller_16-11-07_19_58_34_522.xml",
  "screenAnalysis.grade": "100",
  "timer.device": "0"}